Applications:
• waters, aquaristics, fish farming
• drinking water and process monitoring
• soil measurements
• food production and control
• swimming pools
• education
Specifications:
Measuring range: 0.00 ... 14.00 pH with pH electrode GE 114
-5.0 … +150.0 °C (23.0 … 302.0 °F) with temperature probe GTF 55 B
with optionally available ORP electrode GE 105-BNC: -1999 ... +2000 mV
Resolution: 0.01 pH / 0.1 °C
Accuracy (only device): ± 0.01 pH ± 1 digit, ± 0.2 °C (at nominal temperature 25 °C in measuring range -5 ...100 °C)
Connections: BNC bayonet for electrode, 2x 4mm banana sockets for temperature, 3.5 mm stereo jack socket for interface/analog output
pH electrode: GE 114 (standard electrode, included) combination electrode with gel electrolyte. Measuring range: 0-14 pH, temperature 0-60 °C, applicable for conductivities >200 µS/cm
Temperature probe: GTF 55 B (Pt1000 temperature probe, included)
EMC: The device corresponds to the essential protection ratings established in the Regulations of the Council for the Approximation of Legislation for the member countries regarding electromagnetic compatibility (2004/108/EG).
additional error: <1 %
Scope of supply: measuring device, pH electrode GE 114, temperature probe GTF 55 B, buffer capsules GPH 4 and GPH 7 (5x of each type), 2 wide mouth bottles GPF 100, battery, manual
• waters, aquaristics, fish farming
• drinking water and process monitoring
• soil measurements
• food production and control
• swimming pools
• education
Specifications:
Measuring range: 0.00 ... 14.00 pH with pH electrode GE 114
-5.0 … +150.0 °C (23.0 … 302.0 °F) with temperature probe GTF 55 B
with optionally available ORP electrode GE 105-BNC: -1999 ... +2000 mV
Resolution: 0.01 pH / 0.1 °C
Accuracy (only device): ± 0.01 pH ± 1 digit, ± 0.2 °C (at nominal temperature 25 °C in measuring range -5 ...100 °C)
Connections: BNC bayonet for electrode, 2x 4mm banana sockets for temperature, 3.5 mm stereo jack socket for interface/analog output
pH electrode: GE 114 (standard electrode, included) combination electrode with gel electrolyte. Measuring range: 0-14 pH, temperature 0-60 °C, applicable for conductivities >200 µS/cm
Temperature probe: GTF 55 B (Pt1000 temperature probe, included)
EMC: The device corresponds to the essential protection ratings established in the Regulations of the Council for the Approximation of Legislation for the member countries regarding electromagnetic compatibility (2004/108/EG).
additional error: <1 %
Scope of supply: measuring device, pH electrode GE 114, temperature probe GTF 55 B, buffer capsules GPH 4 and GPH 7 (5x of each type), 2 wide mouth bottles GPF 100, battery, manual