Function and Applications
The Geiger-Mueller Counter tube, 45 mm is a self-extinguishing halogen counting tube for the detection of alpha, beta and gamma radiation. A long plateau (approx. 425 V…650 V) with only a slight slope renders the selection of the operating point uncritical. The actual counting tube, which is mounted in a metal cylinder with BNC socket, has a thinwalled metal sheath that is permeable to alpha radiation.
Benefits
Highly sensitive counting tube
Useful to investigate weakly radioactive sources
Even natural radioactive sources can be investigated
Equipment and Technical Data
Extinguishing material halogen
self-extinguishing halogen counting tube with BNC-plug
including grid to protect the counting tube
Sheath: 2 ... 3 mg/cm2
Operating voltage: 500 V
Length of plateau: 200 V
Slope of plateau: 0,04 %/V
Dead time approx.: ca. 100 µs
Background effect approx.: ca. 45 pulses/min
Diameter of housing: 60 mm (Ring for support rod: 75 mm)
Diameter of counting tube: 45 mm
Length: 80 mm
Mass: 320 g
Screened cable, BNC, l = 750 mm (included, art. no. 07542-11)
Support rod to fix the device is included (with thread, screwable)
Necessary accessories
One of the following counters is required:
Geiger-Müller-Counter 13606-99
or Universal Counter 13601-99
or Cobra4 Sensor-Unit Radioactivity (Cobra4 interface required)
The Geiger-Mueller Counter tube, 45 mm is a self-extinguishing halogen counting tube for the detection of alpha, beta and gamma radiation. A long plateau (approx. 425 V…650 V) with only a slight slope renders the selection of the operating point uncritical. The actual counting tube, which is mounted in a metal cylinder with BNC socket, has a thinwalled metal sheath that is permeable to alpha radiation.
Benefits
Highly sensitive counting tube
Useful to investigate weakly radioactive sources
Even natural radioactive sources can be investigated
Equipment and Technical Data
Extinguishing material halogen
self-extinguishing halogen counting tube with BNC-plug
including grid to protect the counting tube
Sheath: 2 ... 3 mg/cm2
Operating voltage: 500 V
Length of plateau: 200 V
Slope of plateau: 0,04 %/V
Dead time approx.: ca. 100 µs
Background effect approx.: ca. 45 pulses/min
Diameter of housing: 60 mm (Ring for support rod: 75 mm)
Diameter of counting tube: 45 mm
Length: 80 mm
Mass: 320 g
Screened cable, BNC, l = 750 mm (included, art. no. 07542-11)
Support rod to fix the device is included (with thread, screwable)
Necessary accessories
One of the following counters is required:
Geiger-Müller-Counter 13606-99
or Universal Counter 13601-99
or Cobra4 Sensor-Unit Radioactivity (Cobra4 interface required)
Properties
- P0900701