Set
There are 2 variants of this article, view them here >
Features
CAT III 600 V
display: 3 1/2 digit LCD
23 ranges
low battery display function
including: test leads and battery
accuracy: ± (a% reading + b digit)
buzzer
with separate test leads TLM73 (incl.): TLM73: PVC TEST LEAD SET - CAT III 600 V - 12 A - 18 AWG - LENGTH 70 cm
Specifications
DC voltage: 0-200 mV / 2 V / 20 V / 200 V / 600 V
basic accuracy: ± (1.0 % rdg + 2 digits) for 0 to 200 V , ± (1.2 % rdg + 2 digits) for 600 V
input impedance: 10 MOhm
overload protection: 600 V DC or AC rms
AC voltage: 0-200 mV / 2 V / 20 V / 200 V / 600 V
basis accuracy: ± (1.2 % rdg + 3 digits) for 0 to 200 V , ± (1.5 % rdg + 3 digits) for 600 V
input impedance: 10 MOhm
RMS of sine wave value (average value)
overload protection: 600 V DC or AC rms
frequency range: 40 - 500 Hz
DC current: 0-600 µA / 6000 µA / 60 mA / 600 mA / 6 A / 15 A
basic accuracy: ± (1.2 % rdg + 2 digits) for 0 to 20 mA , ± (1.5 % rdg + 2 digits) for 200 mA, ± (2.0 % rdg + 3 digits) for 10 A
overload protection: 0.5 A / 600 V fuse in µA/mA range; 10 A / 600 V fuse in 10 A range
AC current: 0-2 mA / 20 mA / 200 mA / 10 A
basic accuracy: ± (1.5 % rdg + 3 digits) for 0 to 20 mA , ± (2.0 % rdg + 3 digits) for 200 mA, ± (2.5 % rdg + 5 digits) for 10 A
frequency range: 40 - 500 Hz
overload protection: 0.5 A / 600 V fuse in uA/mA range; 10 A / 600 V fuse in 10A range
RMS of sine wave value (Average value)
resistance: 0-200 Ohm / 2 kOhm / 20 kOhm / 200 kOhm / 2 mOhm / 20 mOhm
basic accuracy: ± (1.0% rdg + 3 digits) for 0 to 200 Ohm , ± (1.0 % rdg + 2 digits) for 2 kOhm to 2 mOhm , ± (1.5% rdg + 3 digits) for 20 mOhm
overload protection: 600 V DC or AC rms
open circuit voltage: approx. 0.6 V
diode and audible continuity measurement:
diode: test forward voltage of diode
test voltage: approx. 1.8 V
continuity: < 50 Ohm built-in buzzer sounds
test voltage: approx.1.8 V
transistor hFE test:
hFE: transistor hFE 0-1000
test voltage: approx. 1.8 V
battery: 1.5V x 2 AAA
environmental temperature: 023°c ± 5°c
relative humidity: < 80 %
dimensions: 155 x 74 x 40 mm
weight: 155 g
test lead probe : CAT III 600 V - 12 A - 18 AWG - 70 cm
CAT III 600 V
display: 3 1/2 digit LCD
23 ranges
low battery display function
including: test leads and battery
accuracy: ± (a% reading + b digit)
buzzer
with separate test leads TLM73 (incl.): TLM73: PVC TEST LEAD SET - CAT III 600 V - 12 A - 18 AWG - LENGTH 70 cm
Specifications
DC voltage: 0-200 mV / 2 V / 20 V / 200 V / 600 V
basic accuracy: ± (1.0 % rdg + 2 digits) for 0 to 200 V , ± (1.2 % rdg + 2 digits) for 600 V
input impedance: 10 MOhm
overload protection: 600 V DC or AC rms
AC voltage: 0-200 mV / 2 V / 20 V / 200 V / 600 V
basis accuracy: ± (1.2 % rdg + 3 digits) for 0 to 200 V , ± (1.5 % rdg + 3 digits) for 600 V
input impedance: 10 MOhm
RMS of sine wave value (average value)
overload protection: 600 V DC or AC rms
frequency range: 40 - 500 Hz
DC current: 0-600 µA / 6000 µA / 60 mA / 600 mA / 6 A / 15 A
basic accuracy: ± (1.2 % rdg + 2 digits) for 0 to 20 mA , ± (1.5 % rdg + 2 digits) for 200 mA, ± (2.0 % rdg + 3 digits) for 10 A
overload protection: 0.5 A / 600 V fuse in µA/mA range; 10 A / 600 V fuse in 10 A range
AC current: 0-2 mA / 20 mA / 200 mA / 10 A
basic accuracy: ± (1.5 % rdg + 3 digits) for 0 to 20 mA , ± (2.0 % rdg + 3 digits) for 200 mA, ± (2.5 % rdg + 5 digits) for 10 A
frequency range: 40 - 500 Hz
overload protection: 0.5 A / 600 V fuse in uA/mA range; 10 A / 600 V fuse in 10A range
RMS of sine wave value (Average value)
resistance: 0-200 Ohm / 2 kOhm / 20 kOhm / 200 kOhm / 2 mOhm / 20 mOhm
basic accuracy: ± (1.0% rdg + 3 digits) for 0 to 200 Ohm , ± (1.0 % rdg + 2 digits) for 2 kOhm to 2 mOhm , ± (1.5% rdg + 3 digits) for 20 mOhm
overload protection: 600 V DC or AC rms
open circuit voltage: approx. 0.6 V
diode and audible continuity measurement:
diode: test forward voltage of diode
test voltage: approx. 1.8 V
continuity: < 50 Ohm built-in buzzer sounds
test voltage: approx.1.8 V
transistor hFE test:
hFE: transistor hFE 0-1000
test voltage: approx. 1.8 V
battery: 1.5V x 2 AAA
environmental temperature: 023°c ± 5°c
relative humidity: < 80 %
dimensions: 155 x 74 x 40 mm
weight: 155 g
test lead probe : CAT III 600 V - 12 A - 18 AWG - 70 cm